Machine-Tools.Com complete machine and parts directory/newsgroup   >   By Location   >   Missouri   >   Tektronix P7350SMA 5.0 ghz differential probe with sma

Tektronix P7350SMA 5.0 ghz differential probe with sma


Article Sent By: H.barker@machine--tools.com (Hester Barker)
Hester Barker is presenting: Tektronix P7350SMA 5.0 ghz differential probe with sma
EscrowUnlt © AP6.0quareTrade © AP6.0EscrowUnlt © AP6.0
Condition: Excellent condition – New, Open Box
Tektronix P7350SMA 5.0 GHz Differential Probe with SMA Input
* <100 ps Rise time (Guaranteed)
* Dual SMA inputs to internal 50 Ω termination network
* Internal differential amplifier with high CMRR
* DC Bias Port for Common Mode Voltage termination (LVPECL & CML bias capability)
* Good Differential Input Return Loss
* Supplied with low loss matched delay cables
* TekConnect™ Interface preserves signal integrity to 10 GHz and beyond to meet present and future bandwidth needs
* Communications (Gigabit Ethernet, Fibre Channel, Infiniband)
* Semiconductor Characterization & Validation (PCI-Express, Serial ATA, IEEE 1394, USB 2.0, RAMBUS, DDR)
Tektronix brings you the first-available high-speed differential SMA input probe. The P7350SMA provides a tool for measuring differential signals in a 50 Ω signaling environment. Before the introduction of the P7350SMA, most serial data compliance measurements required cabling a differential signal to two oscilloscope channels and applying waveform math to calculate the difference. By integrating a dual 50 Ω termination network and a differential amplifier in the probe head, the P7350SMA measures a differential signal pair on each channel of a multiple channel oscilloscope. Since many of the new high-speed serial data standards define differential signaling on multiple channels, the P7350SMA provides a more efficient measurement solution.
The P7350SMA probe architecture includes an input termination network, a differential buffer amplifier, and a common mode DC bias port. Since many differential data signals operate with a non-zero DC common mode voltage, the DC bias port allows for more flexible interfacing to these logic families. For applications requiring a common mode DC termination voltage, that voltage can be supplied to the P7350SMA DC bias port through a standard banana plug connector. For other differential measurement applications, such as AC-coupled and some DC-coupled high frequency 8B/10B encoded data streams, the DC bias port can simply be left unconnected.
Input signals use SMA connectors to attach to the input termination network, implemented on a laser-trimmed hybrid circuit for signal fidelity and high frequency response. The linear buffer amplifier converts the differential input signal to a single-ended output and drives the output signal down the probe cable at full bandwidth.
An active differential buffer amplifier in the probe head enables the P7350SMA probe to move the measurement interface from the oscilloscope front panel to the circuit-under-test. This can reduce the length of electrical interconnect cabling, which for multi-gigabit data signals also reduces frequency dependent loss distortion in signal measurements.
<100 ps 10% - 90% (guaranteed)
Bandwidth (Probe Only) - 5.0 GHz (typical).
Differential Input Resistance - 100 Ω Â±2%
Common Mode Input Resistance - 50 Ω Â±1%
Differential Input Range - ±2.5 V (20 °C to 30 °C)
Common Mode Input Range - +6.25 V to -5 V
Maximum Termination Resistor Power - <0.5 W per side*
Max Voltage (Non-destruct) - ±15 V (DC plus peak AC)
CMRR - >60 dB at DC, >55 dB at 1 MHz, >50 dB at 30 MHz, >30 dB at 1 GHz (typical)
Differential Input Return Loss
625 MHz (fundamental for 1.25 Gb/s)
1.25 GHz (fundamental for 2.5 Gb/s)
1.56 GHz (fundamental for 3.125 Gb/s)
Noise - Approximately 46 nV/root Hz
1 071-1264-00 INSTRUCTION MANUAL
1 001-1365-00 "READ THIS FIRST" FLYER
2 015-1022-01 MALE SMA TERMINATION(on unit)
1 174-4866-00 DUAL SMA CABLES MATCHED
1 012-1667-00 DUAL BANANA SHORTING PLUG
1 016-1886-00 CABLE MARKERS ( PKG OF 10)
1 015-0572-XX SMA(F)-BNC(M) ADAPTER
1 006-3415-04 ANTI-STATIC WRIST STRAP
Comes with 90 Day CRI warranty, repair, refund or exchange if the unit does not meet manufactures specifications.
We are required to collect sales tax in all eligible states unless a resale or exemption certificate is provided.
http:// /corporate/leasing/cc_for_sales.pdf
Ø Please include your telephone number at checkout to ensure proper delivery.
Ø International Orders please include your Region, telephone number, Zip Code and VAT number.
CRI has been in business in excess of 44 years with a net worth of $52 mil. We have been renting, leasing and selling T&M equipment since 1962. We have 9 sales locations throughout the country. Our Metrology Lab and Computer Warehouse are located in Hudson, NH. Continental Resources is ISO 9001:2000 Registered and our Calibration Certificates are tracable to NIST.
(please look at our rules and privacy policy)
Contact H.barker@machine--tools.com (Hester Barker) for additional information. This email is used for forwarding to newsgroup user.